OVERVIEW
The HQK-71 series floating ball liquid level controller is a top mounted liquid level measuring instrument for containers, especially ideal for measuring the liquid level of underground and semi underground storage tanks. Tested media: water, industrial wastewater, various oil products, and liquid media such as acids and alkalis. The HQK-71 series floating ball liquid level controller consists of two parts: a liquid level sensor and a display controller. The liquid level sensor consists of magnetic float, measuring conduit, connecting flange (or thread or support plate), and junction box and other components. The float floats up and down along the conduit with the change of liquid level, and through magnetic coupling, the corresponding reed switch in the conduit absorbs and outputs the switch signal or resistance signal at the corresponding position. The switch signal is used for remote alarm or liquid level control; The resistance signal is converted to output a 4-20mA signal for remote liquid level display.
Types of liquid level sensors
According to the nature of output signal, sensors can be divided into four types:
- High power reed switch signal direct output type.
MODEL: HQK-71G - Low power reed switch signal output type.
MODEL: HQK-71K - Analog output type (4-20mA. DC)
MODEL: HQK-71M - Multi floating ball type: model HQK-71DQ

TECHNICAL PARAMETER
- Measurement range H: ≤ 6000mm
- Measurement error: ± 5mm
- Dry reed tube capacity: High power tube: 220V AC, 2A Low power tube: 24V DC, 0.3A
- Work pressure: ≤ 4.0MPa
- Medium temperature: -20~120 º C (special design when>120 º C)
- Medium density: ≥ 0.45g/cm3
- Medium viscosity: ≤ 1.25st
- Wetting material: 1Cr18Ni9Ti, 316, PVC plastic
- Explosion proof grade: d Ⅱ BT1-4 Explosion proof certificate number: GYB55339
- Protection level: IP66